以质量求发展,以服务铸品牌

Journal of Nursing ›› 2023, Vol. 30 ›› Issue (10): 7-10.doi: 10.16460/j.issn1008-9969.2023.10.007

Previous Articles     Next Articles

Consistency of common temperature measurement methods and its enlightenment to teaching of Fundamental Nursing

LI Cai-ying1a, SU Yu-fang1b, JIN Mu2, ZHAO Xue-ping2, ZHAO Xin1a   

  1. 1a. Dept. of Nursing Administration, 1b. Dept. of Orthopaedics, the First Affiliated Hospital of Soochow University, Suzhou 215006, China;
    2. Suzhou Medical College of Soochow University, Suzhou 215006, China
  • Received:2023-01-13 Online:2023-05-25 Published:2023-06-08

Abstract: Objective To compare the difference and consistency between the temperature measured by ear thermometer, non-contact infrared thermometer and oral temperature measured by mercury thermometer, and to find a temperature measurement method to replace mercury thermometer. Methods A total of 720 orthopedic inpatients from March to May 2021 were selected by convenience sampling. Tympanic temperature was measured with an ear thermometer. Forehead, behind the ear and Neiguan temperature were measured with a non-contact infrared thermometer, and oral temperature was measured with a mercury thermometer as standard reference. Paired t test and Bland-Altman analysis were used to compare the differences and consistency between the temperature measured by these four temperature measurement methods and oral temperature. Results Among the four temperature measurement methods, only the difference between retroauricular temperature and oral temperature was statistically significant (P<0.001). The 95% limit of agreement between tympanic temperature and oral temperature was the narrowest (-0.605, 0.601), and the data points outside the 95% consistency limit accounted for 3.06%, which were better than those measured by other temperature measurement methods. Conclusion The consistency between tympanic temperature measured by ear thermometer and oral temperature measured by mercury thermometer is relatively good. Mercury thermometer can be replaced by ear thermometer after it is discontinued.

Key words: body temperature, mouth temperature, tympanic membrane temperature, ear thermometer, mercury thermometer, Bland-Altman

CLC Number: 

  • R47
[1] 国家药品监督管理局. 国家药监局综合司关于履行《关于汞的水俣公约》有关事项的通知[EB/OL].(2020-10-16)[2023-03-10]https://www.nmpa.gov.cn/xxgk/fgwj/gzwj/gzwjylqx/20201016150908105.html.
[2] 管燕璐,杨丹丹,张薇,等. 新型冠状病毒肺炎疫情期间Ⅰ期临床试验病房及受试者管理[J]. 护理学报, 2021, 28(15):60-62. DOI:10.16460/j.issn1008-9969.2021.15.060.
[3] 力敏,赖钦涛,冷芬,等. 新型冠状病毒肺炎重点疫区人员航空转运中感染防控策略[J]. 护理学报, 2020, 27(14): 59-62. DOI:10.16460/j.issn1008-9969.2020.14.059.
[4] 李小寒,尚少梅. 基础护理学[M]. 7版.北京:人民卫生出版社,2022:211-214.
[5] Kameda N.Clinical accuracy of non-contact forehead infrared thermometer and infrared tympanic thermometer in postoperative adult patients: a comparative study[J]. J Perioper Prac, 2022, 32(6):142-148.DOI:10.1177/17504589211022314.
[6] Dante A, Franconi I, Marucci AR, et al.Evaluating the interchangeability of forehead, tympanic, and axillary thermometers in italian paediatric clinical settings: results of a multicentre observational study[J]. J Pediatr Nurs,2020,52:e21-e25.DOI:10.1016/j.pedn.2019.11.014.
[7] Dante A, Gaxhja E, Masotta V, et al.Evaluating the interchangeability of infrared and digital devices with the traditional mercury thermometer in hospitalized pediatric patients: an observational study[J]. Sci Rep, 2021, 11(1). DOI:10.1038/s41598-021-96587-y.
[8] 李镒冲,李晓松. 两种测量方法定量测量结果的一致性评价[J]. 现代预防医学, 2007(17): 3263-3266.
[9] Altman DG, Bland JM.Measurement in medicine: the analysis of method comparison studies[J]. J R Stat Soc Series D (Statist),1983,32(3):307-317.DOI:10.2307/2987937.
[10] Zaki R,Bulgiba A,Ismail R,et al.Statistical methods used to test for agreement of medical instruments measuring continuous variables in method comparison studies: a systematic review[J]. PLoS One, 2012,7(5): e37908. DOI:10.1371/journal.pone.0037908.
[11] Bland JM, Altman DG.Statistical methods for assessing agreement between two methods of clinical measurement[J]. Lancet,1986,1(8476):307-310. DOI:10.1016/S0140-6736(86)90837-8.
[12] 钟伟华. Bland-Altman方法一致性评价报告规范研究[D]. 广州:南方医科大学, 2017.
[13] 刁玲玲,赵晓玲,张婷婷,等. 三种体温测量方法的一致性评价[J]. 护理学杂志, 2018, 33(11):49-51.
[14] Basak T, Aciksoz S,Tosun B,et al. Comparison of three different thermometers in evaluating the body temperature of healthy young adult individuals[J]. Int J Nurs Pract, 2013: n/a-n/a. DOI: 10.1111/ijn.12097.
[15] Deborah Gates V H. Temperature Measurements: Comparison of Different Thermometer Types for Patients With Cancer[J]. Clin J Oncol Nurs, 2018. DOI:10.1188/18.CJON.611-617.
[16] Aadal L, Fog L, Pedersen A R.Tympanic ear thermometer assessment of body temperature among patients with cognitive disturbances. An acceptable and ethically desirable alternative?[J]. Scand J Caring Sci, 2016, 30(4):766-773. DOI:10.1111/scs.12303.
[17] 钱宇,王艳,黎萌,等. 非侵入式体温测量设备在临床体温测量准确度研究[J]. 生物医学工程与临床, 2022:1-8. DOI:10.13339/j.cnki.sglc.20220421.005.
Viewed
Full text


Abstract

Cited

  Shared   
[1] HE Jia-qi, HAO Xi-jun, CHEN Chang-xiang. Social integration dilemma of elderly migrants and its influencing factors: a 854-case study[J]. Journal of Nursing, 2023, 30(9): 1 -6 .
[2] ZHOU Meng-juan, ZHU Xiao-li, ZHANG Tai, DUAN Jian-feng, LUO Yu-mei, MA Wei-li, LU Han, SHI Ting-ting, YANG Yi-lin, LI Ting, CHA Yao-lei, ZHAO Yuan. Construction and verification of predictive model for prolonged length of stay in patients with non-severe acute pancreatitis[J]. Journal of Nursing, 2023, 30(9): 7 -12 .
[3] LV Lu-yang, WANG Hua-fen, LU Fang-yan, WANG Yan, JIANG Shu-ying. Experience of readiness for discharge of family caregivers of children with liver transplantation: a qualitative study[J]. Journal of Nursing, 2023, 30(9): 13 -17 .
[4] . [J]. Journal of Nursing, 2023, 30(9): 18 -24 .
[5] ZHANG Nan, MA Li, LIU Guang-ying, ZHOU Xue-tong, AN Xiao-hua, TENG Min. Plan-Do-Check-Act practice of shortening preparation time of Da Vinci robotic operation[J]. Journal of Nursing, 2023, 30(9): 25 -29 .
[6] . [J]. Journal of Nursing, 2023, 30(9): 30 -32 .
[7] . [J]. Journal of Nursing, 2023, 30(9): 33 -36 .
[8] YANG Yan, DONG Si-qin, ZHAO Bao-sheng, LI Zhen-xiang. Best evidence summary for exercise management for patients in early and middle stage of Parkinson's disease[J]. Journal of Nursing, 2023, 30(9): 37 -42 .
[9] . [J]. Journal of Nursing, 2023, 30(9): 43 -48 .
[10] . [J]. Journal of Nursing, 2023, 30(9): 49 -54 .